High Frequency Intraoral Dental X-ray
HATCH X-RAY
High Frequency Intraoral Dental X-ray
By incorporating Innovative Technologies and the latest Dual Microprocessors, Hatch X-Ray has packed the power and intelligence in a number of ways to enhance the convenience of the clinician and patients
- The unique shielding technology results in negligible leakage radiation. This ensures that both the patients and clinicians are safely protected from unwanted radiation
- The sleek design of the X-Ray tube -head coupled with an in-built short cone, enables it to be positioned at any angle and direction with ease to get good images.
- X-ray of stable and fine quality is produced by the 100kHz digital generator, offering good quality at a minimum dose.
- Tube head swivel on horizontal plane 540º
By incorporating Innovative Technologies and the latest Dual Microprocessors, Hatch X-Ray has packed the power and intelligence in a number of ways to enhance the convenience of the clinician and patients
- The unique shielding technology results in negligible leakage radiation. This ensures that both the patients and clinicians are safely protected from unwanted radiation
- The sleek design of the X-Ray tube -head coupled with an in-built short cone, enables it to be positioned at any angle and direction with ease to get good images.
- X-ray of stable and fine quality is produced by the 100kHz digital generator, offering good quality at a minimum dose.
- Tube head swivel on horizontal plane 540º
- Innovative Technologies
- Research Driven Products
- Affordable
- Support
Share
Smooth and Stable
The smooth drift-free positioner allows you to trigger the exposure from a distance without concern of a shift in Image position during exposure.
Tube-head Beam Limiting Device
Provides 60 kV – 70 kV voltage range (adjustable in 1 kV steps) and 4 mA–8 mA current range (adjustable in 1 mA steps) to reduce exposure times and the amount of radiation absorbed by the patient.
Technical
Specifications
Line Voltage, Tube Potential
100-110V / 230-240V AC,
Single Φ, 60Hz/50Hz
60kV to 70 kV
(In steps of IkV)
Focal Spot
0.4 mm
Tube Current
4to 8 mA
(In steps of 1 mA)
Applicable Documents Federal Regulations
21 CFR, UL
Options
Extension arm options:
Standard 33” or 24”, 15”
Mounting
Single stud mounting,
Two stud mounting
(optional)
Certifications
ISO 13485:2016
MDSAP
Health Canada
Test Standard
UL listed to Canada standards
Line Voltage, Tube Potential
100-110VAC,
Single Φ, 60Hz
60kV to 70 kV
(In steps of IkV)
Focal Spot
0.4 mm
Tube Current
4mA to 8 mA
(In steps of 1 mA)
Applicable Documents Federal Regulations
21 CFR, UL
Options
Extension arm options:
Standard 33” or 24”, 15”
Mounting
Single stud mounting,
Two stud mounting
(optional)
Certifications
ISO 13485:2016
MDSAP
Health Canada
Test Standard
UL listed to Canada standards
All About
Hatch X-ray
High frequency Intraoral X-ray with elegant ergonomics, stability and power provides high quality intraoral diagnostic radiography.
Smooth and Stable
The smooth, drift-Free positioner allows you to trigger the exposure from a distance without the concern of a shift in Image position during exposure.
Latest and Advanced Design
By incorporating Innovative Technologies and the latest Dual Microprocessors, Hatch x-ray has packed the power and intelligence in a number of ways to enhance the convenience of the clinician and patients. The smooth and drift-free positioner allows you to trigger the exposure from a distance without the concern of a shift in image position during exposure. The sleek console is designed with a graphical LCD to display exposure parameters modes of operations and self-diagnostic messages.
Ease of use
The sleek design of the X-Ray tube-head coupled with an in-built short cone, enables it to be positioned at any angle and direction with ease to get good images.
SkanSHIELDTM
The unique shielding technology results in virtually negligible leakage radiation. This ensures that both patient and clinicians are safely protected from unwanted radiation.
SkanSAFETM
This precise digital control for X-ray generation eliminates soft radiation. Hatch X-Ray is designed and built to comply with global safety and protection standards ensuring safety of the user and equipment in the entire operating range.
Frequently asked questions (FAQ)
The Main Components of a Dental Xray Machines are:
- Tube Head: The Tube Head consists of an anode-cathode filament system It functions as a specific energy converter, receiving electrical energy and converting it into x-radiation and heat.
- This very specific energy conversion takes place in the x-ray tube. The X-Ray tube consists of
- A control PCB: It controls the energy conversion.
- Tube housing: It is fitted with a Position Indicating Device (PID)which X-ray passes through cooling oil: to control and protect from the heat while generating the X-Ray tube cover
- Scissor Arm: The tube head is mounted on the scissor arm and easily can fix the tube head positioning to the patient
- Extension Arm: It determines the Max tube head reaches the patient
- Control Console: The Control Console is the user interface with a display Module. The user can adjust the parameters and select different programs through the console unit
Power generating (High Voltage generator) PCB: the Power PCB generates the high voltage and it delivers to the tube head through a set of Cables (communication interface cables)
- The Tube current mA: The flow of electrons from the cathode to the anode in the X-Ray tube and the measuring unit is mA
- The Kilovoltage Peak KVp: A high voltage potential measured in KVp. It will determine the quality and the intensity of the image. Usually, it will be between 60-70 KVp for dental Xrays.
- The exposure time: Usually it will be measured in ms , the maximum up to a few Sec
3: What PPE should be used when taking and processing dental X-rays?
The main PPE is a lead apron that covers the neck and the body. Also PPE like gloves,
eye safety glass, Mask etc.
- Hatch X-Ray can be fix vertical as well as horizontal positions without any extra parts.
- Hatch X-ray is a high-frequency Dc intraoral Xray it creates high-quality images.
- Hatch Xray have a feedback circuit which will display the exposed factores on the
- display. It can make sure the delivered anergy to the patient.
- Hatch X-Ray can select the KVp And mA by step of 1 unit. It can avoid unwanted radiation
- to the patient.
- Hatch Xray can set a wide range value of ms from 40-3500ms.
- The standard extension arm can reach up to 80”(203mm).
Custom modes are available
3 different extension arm lengths(15”,24” and 33”)
Yes, Hatch X-Ray is registered with Health Canada
All kinds of technical support for troubleshooting as well as installation procedure
through in-person and telephonic.
- Pre Installation setup questions: Hatch Xray has a preinstallation template. It
provides all information to prepare for the installation
- Exposure Parameters questions: The User Manual provides all kinds of parameter
selection.
- Control console button explanations: the user manual provides all the console keys
explanation with images .